成年男女免费视频网站_国产福利精品在线观看_耽美肉文片段_中文字幕一区二区在线播放 - 欧美一级欧美三级在线观看

上海翰粵自動化系統(tǒng)有限公司
免費會員

西門子CPU416

參  考  價面議
具體成交價以合同協(xié)議為準

產(chǎn)品型號

品       牌

廠商性質代理商

所  在  地上海市

聯(lián)系方式:瞿曉明查看聯(lián)系方式

更新時間:2016-05-09 16:32:16瀏覽次數(shù):126次

聯(lián)系我時,請告知來自 儀表網(wǎng)
西門子CPU416,SIMATIC S7-400,CPU 416-2DP: 5.6MB(2.8MB代碼,2.8MB數(shù)據(jù)),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP

西門子CPU416,CPU416,西門子S7-400CPU416,西門子CPU416可編程控制器,*處理器,SIMATIC S7-400,CPU 416-2DP: 5.6MB(2.8MB代碼,2.8MB數(shù)據(jù)),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP

6ES7416-2XN05-0AB0

SIMATIC S7-400,CPU 416-2DP: 5.6MB(2.8MB代碼,2.8MB數(shù)據(jù)),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP

6ES7416-2XP07-0AB0

SIMATIC S7-400, CPU 416-2, CENTRAL PROCESSING UNIT WITH: 8 MB WORKING MEMORY, (4 MB CODE, 4 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP

6ES7416-3ES07-0AB0

SIMATIC S7-400, CPU 416-3 PN/DP CENTRAL PROCESSING UNIT WITH: 16 MB WORKING MEMORY, (8 MB KB CODE, 8 MB DATA), INTERFACES: 1. IF MPI/DP 12 MBIT/S (X1), 2. IF ETHERNET/PROFINET (X5), 3. IF IF964-DP PLUGABLE (IF1)

6ES7416-3XR05-0AB0

SIMATIC S7-400,CPU 416-3DP: 11.2MB(5.6MB代碼,5.6MB數(shù)據(jù)),位處理速度30ns,集成接口:1. MPI/DP, 2. PROFIBUS DP, 3. 可擴展的IF964-DP(IF1)接口

6ES7416-3XS07-0AB0

SIMATIC S7-400, CPU 416-3, CENTRAL PROCESSING UNIT WITH: 16 MB WORKING MEMORY, (8 MB KB CODE, 8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3. IF IFM MODULES PLUGGABLE

 

德國* 現(xiàn)貨銷售 質保一年 歡迎詢價

SIEMENS 上海翰粵自動化系統(tǒng)有限公司

瞿曉明(銷售工程師)

1324375156

 

  概述

  • 性能范圍內的高性能 CPU
  • 適用于對性能要求很高的工廠
  • CPU 416-3 PN/DP 中集成了 PROFINET 功能

 

CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.

The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.

An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.

The integrated PROFINET interface of the CPU 416-3 PN/DP includes switch functionality when the ERTEC 400-ASIC is used. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.

Note:
Only the 6ES7 964-2AA04-0AB0 interface submodule may be used.

  設計

Both CPUs are equipped with the following:

  • Powerful processor: 
    The CPUs achieve instruction execution times as low as 0.03 µs per binary instruction.
  • CPU 416-2: 5.6 MB RAM (of which 2.8 MB each for program and data); 
    CPU 416-3: 11.2 MB RAM (of which 5.6 MB each for program and data); 
    CPU 416-3 PN/DP: 11.2 MB RAM (of which 5.6 MB each for program and data); 
    fast RAM for parts of the user program relevant to execution.
  • Flexible expansion: 
    Up to 262144 digital and 16384 analog inputs/outputs.
  • Multi-point interface MPI: 
    With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
  • Mode selector switch: 
    Designed as toggle switch.
  • Diagnostics buffer: 
    The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
  • Real-time clock: 
    The date and time are appended to diagnostic messages of the CPU.
  • Memory card: 
    For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available
  • Combined MPI/DP interface and integrated PROFIBUS DP interface (CPU 416-2 and CPU 416-3): 
    The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming). 
    Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.

CPU 416-3 and CPU 416-3 PN/DP also include:

  • A module slot: 
    An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module.

CPU 416-3 PN/DP additionally includes:

  • PROFINET interface with 2 ports (switch):
    • PROFINET I/O, 256 IO devices connectable
    • PROFINET CBA

  功能

  • Block protection: 
    A password concept protects the user program from unauthorized access.
  • Integral HMI services: 
    The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
  • Integrated communications functions:
    • PG/OP communication
    • Shared data communication
    • S7 standard communication
    • S7 communication
  • Firmware update using network

CPU 416-3 PN/DP additional:

  • Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
  • Distributed inligence in Component Based Automation (CBA) on PROFINET
  • Additional diagnostic options with integrated web server

Parameterizable attributes

The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.

  • Multi-point interface MPI:
    • Definition of station addresses.
    • Startup/cycle behavior
    • Stipulation of the maximum cycle time and communications load
  • Address assignment: 
    Addressing of I/O modules.
  • Retentive ranges: 
    Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.
  • Size of the process image, local data.
  • Length of the diagnostics buffer
  • Protection level: 
    Definition of access authorization for program and data
  • System diagnostics: 
    Definition of the handling and scope of diagnostic messages
  • Timed interrupts: 
    Setting of periodicity

CPU 416-3 PN/DP additional:

  • PROFINET interface
  • Parameterization of time synchronization using NTP procedure

Indication and information functions

  • Status and error indicators: 
    LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example
  • Test functions: 
    The programming device can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components
  • Information functions: 
    The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories

 

Order number

6ES7416-2XP07-0AB0

6ES7416-3XS07-0AB0

6ES7416-3ES07-0AB0

 

CPU 416-2, MPI, PROFIBUS, 8 MB

CPU 416-3, 16 MB, 3 INTERFACES

CPU416-3 PN/DP, 16 MB, 3 INTERFACES

General information

 

 

 

Product type designation

CPU 416-2

CPU 416-3

CPU416-3 PN/DP

Engineering with

 

 

 

  • ● Programming package

STEP 7 V5.4 or higher with HSP 261

STEP 7 V5.4 or higher with HSP 261

STEP 7 V5.5 or higher with HSP 262

Supply voltage

 

 

 

Rated value (DC)

 

 

 

  • ● 24 V DC

No; Power supply via system power supply

No; Power supply via system power supply

No; Power supply via system power supply

Power loss

 

 

 

Power loss, typ.

4.5 W

5.5 W

6.5 W

Memory

 

 

 

Work memory

 

 

 

  • ● integrated

8 Mbyte

16 Mbyte

16 Mbyte

  • ● integrated (for program)

4 Mbyte

8 Mbyte

8 Mbyte

  • ● integrated (for data)

4 Mbyte

8 Mbyte

8 Mbyte

Load memory

 

 

 

  • ● expandable FEPROM, max.

64 Mbyte

64 Mbyte

64 Mbyte

  • ● integrated RAM, max.

1 Mbyte

1 Mbyte

1 Mbyte

  • ● expandable RAM, max.

64 Mbyte

64 Mbyte

64 Mbyte

CPU processing times

 

 

 

for bit operations, typ.

12.5 ns

12.5 ns

12.5 ns

for word operations, typ.

12.5 ns

12.5 ns

12.5 ns

for fixed point arithmetic, typ.

12.5 ns

12.5 ns

12.5 ns

for floating point arithmetic, typ.

25 ns

25 ns

25 ns

Counters, timers and their retentivity

 

 

 

S7 counter

 

 

 

  • ● Number

2 048

2 048

2 048

IEC counter

 

 

 

  • ● present

Yes

Yes

Yes

S7 times

 

 

 

  • ● Number

2 048

2 048

2 048

IEC timer

 

 

 

  • ● present

Yes

Yes

Yes

Data areas and their retentivity

 

 

 

Flag

 

 

 

  • ● Number, max.

16 kbyte; Size of bit memory address area

16 kbyte; Size of bit memory address area

16 kbyte; Size of bit memory address area

Address area

 

 

 

I/O address area

 

 

 

  • ● Inputs

16 kbyte

16 kbyte

16 kbyte

  • ● Outputs

16 kbyte

16 kbyte

16 kbyte

Process image

 

 

 

  • ● Inputs, adjustable

16 kbyte

16 kbyte

16 kbyte

  • ● Outputs, adjustable

16 kbyte

16 kbyte

16 kbyte

Time of day

 

 

 

Clock

 

 

 

  • ● Hardware clock (real-time clock)

Yes

Yes

Yes

Operating hours counter

 

 

 

  • ● Number

16

16

16

Interfaces

 

 

 

Interfaces/bus type

1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP

1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP, 1 x PROFIBUS DP (optionally pluggable)

1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports), 1 x PROFIBUS DP (optionally pluggable)

Number of RS 485 interfaces

2; Combined MPI / PROFIBUS DP and PROFIBUS DP

2; Combined MPI / PROFIBUS DP and PROFIBUS DP

1; Combined MPI / PROFIBUS DP

Number of other interfaces

 

1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

1. Interface

 

 

 

Interface type

Integrated

Integrated

Integrated

Physics

RS 485 / PROFIBUS + MPI

RS 485 / PROFIBUS + MPI

RS 485 / PROFIBUS + MPI

Functionality

 

 

 

  • ● MPI

Yes

Yes

Yes

  • ● DP master

Yes

Yes

Yes

  • ● DP slave

Yes

Yes

Yes

DP master

 

 

 

  • ● Number of DP slaves, max.

32

32

32

2. Interface

 

 

 

Interface type

Integrated

Integrated

PROFINET

Physics

RS 485 / PROFIBUS

RS 485 / PROFIBUS

Ethernet RJ45

Interface types

 

 

 

  • ● Number of ports

 

 

2

Functionality

 

 

 

  • ● DP master

Yes

Yes

No

  • ● DP slave

Yes

Yes

No

  • ● PROFINET IO Controller

 

 

Yes

  • ● PROFINET IO Device

 

 

Yes

  • ● PROFINET CBA

 

 

Yes

DP master

 

 

 

  • ● Number of DP slaves, max.

125

125

 

3. Interface

 

 

 

Interface type

 

Pluggable interface module (IF), technical data as for 2nd interface

Pluggable interface module (IF)

Plug-in interface modules

 

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Physics

 

RS 485 / PROFIBUS

RS 485 / PROFIBUS

Functionality

 

 

 

  • ● MPI

 

No

No

  • ● DP master

 

Yes

Yes

  • ● DP slave

 

Yes

Yes

DP master

 

 

 

  • ● Number of DP slaves, max.

 

125

125

Isochronous mode

 

 

 

Isochronous operation (application synchronized up to terminal)

Yes; For PROFIBUS only

Yes; For PROFIBUS only

Yes; Via PROFIBUS DP or PROFINET interface

Communication functions

 

 

 

PG/OP communication

Yes

Yes

Yes

Data record routing

Yes

Yes

Yes

Global data communication

 

 

 

  • ● supported

Yes

Yes

Yes

S7 basic communication

 

 

 

  • ● supported

Yes

Yes

Yes

S7 communication

 

 

 

  • ● supported

Yes

Yes

Yes

S5 compatible communication

 

 

 

  • ● supported

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Standard communication (FMS)

 

 

 

  • ● supported

Yes; Via CP and loadable FB

Yes; Via CP and loadable FB

Yes; Via CP and loadable FB

Open IE communication

 

 

 

  • ● TCP/IP

 

 

Yes; via integrated PROFINET interface and loadable FBs

  • — Number of connections, max.

 

 

94

  • ● ISO-on-TCP (RFC1006)

Via CP 443-1 and loadable FB

Via CP 443-1 and loadable FB

Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs

  • — Number of connections, max.

 

 

94

  • ● UDP

 

 

Yes; via integrated PROFINET interface and loadable FBs

  • — Number of connections, max.

 

 

94

Web server

 

 

 

  • ● supported

No

No

Yes

Number of connections

 

 

 

  • ● overall

96

96

96

Standards, approvals, certificates

 

 

 

Use in hazardous areas

 

 

 

  • ● ATEX

ATEX II 3 G Ex nA IIC T4 Gc

ATEX II 3 G Ex nA IIC T4 Gc

ATEX II 3 G Ex nA IIC T4 Gc

Ambient conditions

 

 

 

Ambient temperature during operation

 

 

 

  • ● min.

0 °C

0 °C

0 °C

  • ● max.

60 °C

60 °C

60 °C

Configuration

 

 

 

Know-how protection

 

 

 

  • ● User program protection/password protection

Yes

Yes

Yes

  • ● Block encryption

Yes; With S7 block Privacy

Yes; With S7 block Privacy

Yes; With S7 block Privacy

Dimensions

 

 

 

Width

25 mm

50 mm

50 mm

Height

290 mm

290 mm

290 mm

Depth

219 mm

219 mm

219 mm

Weights

 

 

 

Weight, approx.

700 g

900 g

900 g

 